Sign In | Join Free | My enlightcorp.com
China SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD logo
SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Verified Supplier

5 Years

Home > Low Smoke Halogen Free Cable >

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

Brand Name : DONGJIAXIN

Model Number : WDZ-YJV

Certification : IEC, Rosh,CCC

Place of Origin : CHINA

MOQ : Negotiable

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 100KM/Week

Delivery Time : 7-15 working days

Packaging Details : Steel wooden drum

Model name : WDZ-YJV

Rated Voltage : 0.6/1kV

specification : 1.5~600mm2

insulator : XLPE

Conductor Type : Stranded Bear Copper

Sheath : pvc

High Light : lszh power cables, 4 Core Fire Resistant Cable

Application : home appliance , low voltage installation system,

Contact Now

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor

Fire resistant cable Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Fire resistant cable Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

Product type Conductor structure(mm) Insulation thickness(mm) Sheath thickness(mm) Approx. cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.8 1.4 5.2 12.1
1×2.5 1 0.8 1.4 5.6 7.41
1×4 1 1.0 1.4 6.0 4.61
1×6 1 1.0 1.4 6.5 3.08
1×10 7 1.0 1.4 7.6 1.83
1×16 7 1.0 1.4 8.6 1.15
1×25 7 1.2 1.4 10.2 0.727
1×35 7 1.2 1.4 11.2 0.524
1×50 10 1.4 1.4 12.5 0.387
1×70 14 1.4 1.4 14.3 0.268
1×95 19 1.6 1.5 16.5 0.193
1×120 24 1.6 1.5 18.2 0.153
1×150 30 1.8 1.6 20.1 0.124
1×185 37 2.0 1.7 22.2 0.0991
1×240 48 2.2 1.8 24.9 0.0754
1×300 61 2.4 1.9 27.5 0.0601
1×400 61 2.6 2.0 30.8 0.0470

INSTALLATION METHOD DETAILS

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
C – Embedded in the brickwork D – Buried in additional mechanical protection

* Dimensions and specifications may be changed without prior notice.

Standards&Certificates:
International: IEC 60502-1
National:GB/ T 12706.1-2008

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

▼ Delivery Port :

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
Port of Shenzhen Port of Hongkong

Port of Guangzhou

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
3×4+1×2.5 1 0.7 1.8 14.0 4.61
3×6+1×4 1 0.7 1.8 15.1 3.08
3×10+1×6 7 0.7 1.8 17.3 1.83
3×16+1×10 7 0.7 1.8 19.8 1.15
3×25+1×16 7 0.9 1.8 23.3 0.727
3×35+1×16 7 0.9 1.8 25.1 0.524
3×50+1×25 10 1.0 1.8 29.4 0.387
3×70+1×35 14 1.1 1.9 33.5 0.268
3×95+1×50 19 1.1 2.1 38.1 0.193
3×120+1×70 24 1.2 2.2 42.5 0.153
3×150+1×70 30 1.4 2.3 45.8 0.124
3×185+1×95 37 1.6 2.5 51.2 0.0991
3×240+1×120 48 1.7 2.6 57.0 0.0754
3×300+1×150 61 1.8 2.8 62.6 0.0601
3×400+1×185 61 2.0 3.1 70.1 0.0470
3×500+1×240 61 2.2 3.3 78.3 0.0366
3×630+1×300 61 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
3×4+2×2.5 1 0.7 1.8 15.1 4.61
3×6+2×4 1 0.7 1.8 16.2 3.08
3×10+2×6 7 0.7 1.8 18.5 1.83
3×16+2×10 7 0.7 1.8 21.3 1.15
3×25+2×16 7 0.9 1.8 24.9 0.727
3×35+2×16 7 0.9 1.8 26.6 0.524
3×50+2×25 10 1.0 1.8 31.4 0.387
3×70+2×35 14 1.1 2.0 35.6 0.268
3×95+2×50 19 1.1 2.1 40.4 0.193
3×120+2×70 24 1.2 2.3 45.5 0.153
3×150+2×70 30 1.4 2.4 48.5 0.124
3×185+2×95 37 1.6 2.5 54.2 0.0991
3×240+2×120 48 1.7 2.7 60.3 0.0754
3×300+2×150 61 1.8 2.9 66.5 0.0601
3×400+2×185 61 2.0 3.2 74.3 0.0470
3×500+2×240 61 2.2 3.5 83.1 0.0366
3×630+2×300 61 2.4 3.8 97.0 0.0283

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor


Product Tags:

N2X2Y Flame Retardant Cables

      

WDZ-YJY Flame Retardant Cables

      

600mm2 Flame Retardant Cables

      
Quality WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor for sale

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)